Double Balloon Angioplasty for Unstentable Right Coronary Stenosis

Double Balloon Angioplasty for Unstentable Right Coronary Stenosis
Despite newer lower-profile stent technologies, placing coronary stents may still remain challenging when vessels are extremely tortuous. We describe a case of a very large-caliber right coronary artery (RCA) with a "shepherd's crook" configuration, which could not be stented, and for which double balloon angioplasty was successfully performed.

A 69-year-old Caucasian male was hospitalized for an acute coronary syndrome. Diagnostic heart catheterization revealed a 90% eccentric stenosis past the genu of the right coronary artery. The vessel was large, about 7 mm in caliber, and somewhat patulous, with a prominent "shepherd's crook" configuration (a dramatic upturn with a near-180º switchback turn) (Figure 1).



(Enlarge Image)





Severe stenosis near genu of large, tortuous right coronary artery with extreme "shepherd's crook" configuration.





We employed an 8 Fr system to improve backup support, and attempted to use various guide catheters for optimization including an Amplatz left 3 (Cordis Corp., Miami Lakes, Florida) and Voda right 2 (Boston Scientific Corp., Natick, Massachusetts), but found the best support with an Amplatz left 2 curve (Cordis). We were able to predilate the lesion with a 4.0 x12 mm Sprinter balloon catheter (Medtronic, Inc., Minneapolis, Minnesota) inflated to 12 atm for 30 seconds over a Balance Middle Weight Universal (BMW) 0.014 inch guidewire (Guidant Corp., Santa Clara, California), with luminal improvement. We attempted to place a Herculink 6.0 x 15 mm stent (Guidant) at the site of the stenosis, however, it could not navigate the proximal tortuous bend. The wire was exchanged for an Iron Man 0.014 inch guidewire (Guidant) for better support, but the stent still would not go around the first bend. A 5.0 x 22 mm NC Ranger balloon catheter (Boston Scientific Scimed, Maple Grove, Minnesota) was tried unsuccessfully, as was a 7.0 x 20 mm peripheral balloon, also unsuccessfully. To help facilitate the distalexcursion of these balloons, a BMW universal 0.014 inch guidewire was employed as a "buddy wire".

We then placed the original 4.0 x 12 mm Sprinter balloon at the stenosis and, adjacent to it, a second Sprinter (4.0 x 15 mm), and inflated them simultaneously, side by side at 8 atm each, however, the result was suboptimal. Thus, we tried a Grand Slam guidewire (Abbott Vascular Devices, Redwood City, California) with a 6.0 Symmetry balloon catheter (Boston Scientific) along with the buddy wire, unsuccessfully, and then the NC Ranger balloon catheter again, also unsuccessfully.

Next, we tried to place an Absolute stent (Guidant) at the lesion, attempting to anchor the mid-vessel with the NC Ranger balloon catheter to better seat the guide as the stent came around the shepherd's crook. As this did not help, we then tried placing 2 NC Rangers side by side, but these balloon catheters were unable to reach the lesion.

Ultimately, we had to resort to placing the 2 Sprinter balloons again, as before, and dilated each simultaneously to 20 atm for 50 seconds. (Figure 2). We were finally able to achieve a satisfactory result (Figure 3). The patient has remained symptom-free 1.5 years later.



(Enlarge Image)





Angioplasty of the right coronary artery with simultaneous balloon inflations.







(Enlarge Image)





Right coronary angiogram with significant stenosis resolution.





Coronary balloon and stent technologies have significantly advanced, but there are still situations where coronary anatomy challenges even our newest tools. Our case exemplifies a very large-caliber, tortuous right coronary anatomy precluding the placement of a large-caliber stent, and requiring instead the placement of 2 very low-profile balloon catheters that were inflated simultaneously side by side to achieve adequate lesion dilatation.

SHARE
RELATED POSTS on "Health & Medical"
Heart-Healthy Diet
Heart-Healthy Diet
Effect of Heart Rate Reduction by Ivabradine
Effect of Heart Rate Reduction by Ivabradine
Cholesterol Lowering Statins and Heart Health Misconceptions
Cholesterol Lowering Statins and Heart Health Misconceptions
Discover How to Reduce Cholesterol Naturally
Discover How to Reduce Cholesterol Naturally
Factors Predisposing Women to Heart Disease
Factors Predisposing Women to Heart Disease
Drivers of Hospitalization for Patients With AF
Drivers of Hospitalization for Patients With AF
Congestive Heart Failure & Pain
Congestive Heart Failure & Pain
Heart Disease Systems
Heart Disease Systems
BMI and Health Status in the BARI 2D Trial
BMI and Health Status in the BARI 2D Trial
7) Crocodile Tears For Primary Care
7) Crocodile Tears For Primary Care
The Use of Intra-Aortic Balloon Counterpulsation
The Use of Intra-Aortic Balloon Counterpulsation
Natural Cholesterol Lowering Regime
Natural Cholesterol Lowering Regime
Congenital Heart Disease
Congenital Heart Disease
Measurement of Myocardial Fractional Flow Reserve
Measurement of Myocardial Fractional Flow Reserve
Percutaneous Therapies for Severe Pulmonary Hypertension
Percutaneous Therapies for Severe Pulmonary Hypertension
How to Wreck Your Heart
How to Wreck Your Heart
Hypertension in Urban Underserved Subjects Using Telemedicine
Hypertension in Urban Underserved Subjects Using Telemedicine
Heart Health News Page
Heart Health News Page
Radial vs Femoral Approach in PCI With IABP Support
Radial vs Femoral Approach in PCI With IABP Support
Symptoms of Clogged Arteries in the Legs - How to Know Whether It Is There Or Not
Symptoms of Clogged Arteries in the Legs - How to Know Whether It Is There Or Not

Leave Your Reply

*